Process Advantages
PROCESS

Electrostatic control

 

ALL_advantage_23F06_pdQ0fGk40m 1 (1)

ESD access control

Smart Access Control: Wear antistatic shoes and a wrist strap, and pass the comprehensive ESD tester (electrostatic access control system). The gate will open and grant access only after the test is passed (the resistance value falls within the acceptable range).

ESD shoes: lower limit 1M, upper limit 100M, <3.5*107Ω
Wrist strap lower limit: 1 MΩ; upper limit: 35 MΩ < 3.5*107Ω

1

ESD-controlled production line

Online Monitoring System: Operators wear wired ESD wrist straps connected to real-time online monitors. If a wrist strap becomes loose or grounding fails, the system immediately issues audible and visual alarms.

2
Equipotential bonding throughout the facility

Equipotential bonding throughout the facility: All machinery, worktables, and operators throughout the plant are properly connected to a common ground.

4_processed

Electrostatic-Controlled Warehouse

The warehouse ensures that electronic components and finished products are maintained in a proper ESD-protected environment throughout storage.
  • All electrostatic-sensitive devices must use antistatic packaging upon receipt. When the warehouse receives electrostatic-sensitive devices, it shall inspect whether their packaging complies with ESD protection requirements (especially packaging for leftover quantities); only those meeting the requirements may be accepted into storage.
  • ESD equipment is used to monitor and control everything from the circuit impedance between the warehouse ground wire and the grounding rod, conductive flooring measurements, and machine static electricity measurements to personnel access control.

Real-Time Monitoring System for ESD Grounding Points:
Key advantages of the system:
  • It includes a digital grounding impedance monitor capable of simultaneously monitoring up to 25 input groups.
  • If a measurement abnormality is detected, immediately record it and display the abnormal circuit to facilitate troubleshooting and repair.
  • Provide audible and visual alarm signals in the event of abnormalities.
  • Automatic detection and manual detection functions.
  • Store abnormality records and reports to enable 24-hour monitoring of status.
  • Touchscreen anti-tampering and error-proofing

 

Electrostatic Protection Items Measurement standards
(Ω/SQ)
Frequency Form records Standard
Wrist Strap System <3.5*107Ω Daily (upon entering the SPA) Static Electricity Prevention and Control Network System ANSI/ESD S1.1
Floor/Shoe System <3.5*107Ω Daily (upon entering the SPA) Electrostatic Control Network System ANSI/ESD STM97.1

Privacy Preference Center

We use cookies to enable our website to function properly, personalize content and advertisements, provide social media features, and analyze traffic. We also share information about your use of our website with our social media, advertising, and analytics partners.

View Privacy Policy

Manage consent settings

Necessary Cookies

All enabled

These Cookies are essential for the website to function and cannot be disabled in our systems. They are usually only set in response to actions you take that amount to a request for services, such as setting your privacy preferences, logging in, or filling in forms. You can set your browser to block or alert you about these Cookies, but some website features may not function properly.

Inquiry Cart

total 0 items

Compare

total 0 items

Compare